Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
2.
J Nucl Cardiol ; 27(4): 1118-1125, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-29270771

RESUMO

BACKGROUND: 11C-hydroxyephedrine (HED) PET has been used to evaluate the myocardial sympathetic nervous system (SNS). Here we sought to establish a simultaneous approach for quantifying both myocardial blood flow (MBF) and the SNS from a single HED PET scan. METHODS: Ten controls and 13 patients with suspected cardiac disease were enrolled. The inflow rate of 11C-HED (K1) was obtained using a one-tissue-compartment model. We compared this rate with the MBF derived from 15O-H2O PET. In the controls, the relationship between K1 from 11C-HED PET and the MBF from 15O-H2O PET was linked by the Renkin-Crone model. RESULTS: The relationship between K1 from 11C-HED PET and the MBF from 15O-H2O PET from the controls' data was approximated as follows: K1  =  (1 - 0.891 * exp(- 0.146/MBF)) * MBF. In the validation set, the correlation coefficient demonstrated a significantly high relationship for both the whole left ventricle (r = 0.95, P < 0.001) and three coronary territories (left anterior descending artery: r = 0.96, left circumflex artery: r = 0.81, right coronary artery: r =  0.86; P < 0.001, respectively). CONCLUSION: 11C-HED can simultaneously estimate MBF and sympathetic nervous function without requiring an additional MBF scan for assessing mismatch areas between MBF and SNS.


Assuntos
Circulação Coronária/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Radioisótopos de Carbono , Efedrina/análogos & derivados , Humanos , Radioisótopos de Oxigênio , Estudos Prospectivos , Sistema Nervoso Simpático/fisiologia , Água
3.
Eur J Nucl Med Mol Imaging ; 46(6): 1240-1247, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30327855

RESUMO

PURPOSE: 18F-fluorodeoxyglocose positron emission tomography (FDG PET) plays a significant role in the diagnosis of cardiac sarcoidosis (CS). Texture analysis is a group of computational methods for evaluating the inhomogeneity among adjacent pixels or voxels. We investigated whether texture analysis applied to myocardial FDG uptake has diagnostic value in patients with CS. METHODS: Thirty-seven CS patients (CS group), and 52 patients who underwent FDG PET/CT to detect malignant tumors with any FDG cardiac uptake (non-CS group) were studied. A total of 36 texture features from the histogram, gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM), gray-level zone size matrix (GLZSM) and neighborhood gray-level difference matrix (NGLDM), were computed using polar map images. First, the inter-operator and inter-scan reproducibility of the texture features of the CS group were evaluated. Then, texture features of the patients with CS were compared to those without CS lesions. RESULTS: Twenty-eight of the 36 texture features showed high inter-operator reproducibility with intraclass correlation coefficients (ICCs) over 0.80. In addition, 17 of the 36 showed high inter-scan reproducibility with ICCs over 0.80. The SUVmax showed no difference between the CS and non-CS group [7.36 ± 2.77 vs. 8.78 ± 4.65, p = 0.45, area under the curve (AUC) = 0.60]. By contrast, 16 of the 36 texture features could distinguish CS from non-CS grsoup with AUC > 0.80. Multivariate logistic regression analysis after hierarchical clustering concluded that long-run emphasis (LRE; P = 0.0004) and short-run low gray-level emphasis (SRLGE; P = 0.016) were significant independent factors that could distinguish between the CS and non-CS groups. Specifically, LRE was significantly higher in CS than in non-CS (30.1 ± 25.4 vs. 11.4 ± 4.6, P < 0.0001), with high diagnostic ability (AUC = 0.91), and had high inter-operator reproducibility (ICC = 0.98). CONCLUSIONS: The texture analysis had high inter-operator and high inter-scan reproducibility. Some of texture features showed higher diagnostic value than SUVmax for CS diagnosis. Therefore, texture analysis may have a role in semi-automated systems for diagnosing CS.


Assuntos
Diagnóstico por Computador/métodos , Fluordesoxiglucose F18/análise , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sarcoidose/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Medicine (Baltimore) ; 97(27): e11354, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29979416

RESUMO

We have developed the method for dynamic 320-row multidetector computed tomography (MDCT)-derived quantitative coronary flow reserve (CFRCT) and hyperemic myocardial blood flow (MBFCT). We evaluated diagnostic value of CFRCT and hyperemic MBFCT for detecting obstructive coronary artery disease (CAD) in per-patient and per-vessel analysis, and their relations with the severity of CAD burden.Adenosine stressed and rest dynamic myocardial perfusion MDCT were prospectively performed in patients with known or suspected CAD. Per-patient and per-vessel MBFCT were estimated from dynamic perfusion images in rest and hyperemic phases, and per-patient and per-vessel CFRCT were calculated from the ratio of rest and hyperemic MBFCT. Degree of stenosis was evaluated by coronary CT angiography (CTA) and invasive coronary angiography (ICA). Obstructive stenosis was defined as ≥70% stenosis in ICA. CAD burden with MDCT was calculated by logarithm transformed coronary artery calcium (CAC) score and the CTA-adapted Leaman risk score (CT-LeSc). A logistic regression analysis was used to measure the receiver-operating characteristic curve and corresponding area under the curve (AUC) for the detection of obstructive CAD.Twenty-seven patients and 81 vessels were eligible for this study. Sixteen patients had obstructive CAD, and 31 vessels had obstructive stenosis. Using an optimal cutoff, the CFRCT and hyperemic MBFCT had the moderate diagnostic values in per-patient (AUC = 0.89 and 0.86, respectively) and per-vessel (AUC = 0.79 and 0.76, respectively). Per-patient CFRCT and hyperemic MBFCT exhibited a moderate inverse correlation with CAC score and the CT-LeSc.Per-patient and per-vessel CFRCT as well as hyperemic MBFCT had moderate diagnostic value for detecting obstructive CAD. These per-patient values exhibited a moderate inverse correlation with CAD burden. CFRCT and hyperemic MBFCT might add quantitative functional information for evaluating patients with CAD.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Área Sob a Curva , Angiografia por Tomografia Computadorizada/métodos , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
5.
J Nucl Med ; 58(5): 784-790, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27811122

RESUMO

Diastolic dysfunction is important in the pathophysiology of heart failure with preserved ejection fraction (HFpEF). Sympathetic nervous hyperactivity may contribute to the development of diastolic dysfunction. The aim of this study was to determine the relationship between myocardial sympathetic innervation quantified by 11C-hydroxyephedrine PET and diastolic dysfunction in HFpEF patients. Methods: Forty-one HFpEF patients having an echocardiographic left ventricular ejection fraction of 40% or greater and 12 age-matched volunteers without heart failure underwent the echocardiographic examination and 11C-hydroxyephedrine PET. Diastolic dysfunction was classified into grades 0-3 by Doppler echocardiography. Myocardial sympathetic innervation was quantified using the 11C-hydroxyephedrine retention index (RI). The coefficient of variation of 17-segment RIs was derived as a measure of heterogeneity in myocardial 11C-hydroxyephedrine uptake. Results: Grade 2-3 diastolic dysfunction (DD2-3) was found in 19 HFpEF patients (46%). They had a significantly lower global RI (0.075 ± 0.018 min-1) than volunteers (0.123 ± 0.028 min-1, P < 0.001) and HFpEF patients with grade 0-1 diastolic dysfunction (DD0-1) (0.092 ± 0.024 min-1, P = 0.046). HFpEF patients with DD2-3 had the largest coefficient of variation of 17-segment RIs of the 3 groups (18.4% ± 7.7% vs. 14.1% ± 4.7% in HFpEF patients with DD0-1, P = 0.042 for post hoc tests). In multivariate logistic regression analysis, a lower global RI (odds ratio, 0.66 per 0.01 min-1; 95% confidence interval, 0.38-0.99; P = 0.044) was independently associated with the presence of DD2-3 in HFpEF patients. Conclusion: Myocardial sympathetic innervation was impaired in HFpEF patients and was associated with the presence of advanced diastolic dysfunction in HFpEF.


Assuntos
Doenças do Sistema Nervoso Autônomo/diagnóstico por imagem , Efedrina/análogos & derivados , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Doenças do Sistema Nervoso Autônomo/complicações , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
6.
Pulse (Basel) ; 4(1): 1-10, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27493898

RESUMO

Noninvasive vascular function measurement plays an important role in detecting early stages of atherosclerosis and in evaluating therapeutic responses. In this regard, recently, new vascular function measurements have been developed. These new measurements have been used to evaluate vascular function in coronary arteries, large aortic arteries, or peripheral arteries. Increasing vascular diameter represents vascular remodeling related to atherosclerosis. Attenuated vascular elasticity may be a reliable marker for atherosclerotic risk assessment. However, previous measurements for vascular diameter and vascular elasticity have been complex, operator-dependent, or invasive. Therefore, simple and reliable approaches have been sought. We recently developed a new automated oscillometric method to measure the estimated area (eA) of a brachial artery and its volume elastic modulus (VE). In this review, we further report on this new measurement and other vascular measurements. We report on the reliability of the new automated oscillometric measurement of eA and VE. Based on our findings, this measurement technique should be a reliable approach, and this modality may have practical application to automatically assess muscular artery diameter and elasticity in clinical or epidemiological settings. In this review, we report the characteristics of our new oscillometric measurements and other related vascular function measurements.

7.
Radiol Phys Technol ; 9(1): 77-87, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26493992

RESUMO

This study verified the dose calculation accuracy of the analytical anisotropic algorithm (AAA), Acuros XB version 10 (AXB10), and version 11 (AXB11) installed in an Eclipse treatment planning system, by comparing with Monte Carlo (MC) simulations. First, the algorithms were compared in terms of dose distributions using four types of virtual heterogeneous multi-layer phantom for 6 and 15 MV photons. Next, the clinical head and neck intensity-modulated radiation therapy (IMRT) dose distributions for 6 MV photons were evaluated using dose volume histograms (DVHs) and three-dimensional gamma analysis. In percentage depth doses (PDDs) for virtual heterogeneous phantoms, AAA overestimated absorbed doses in the air cavity, bone, and aluminum in comparison with MC, AXB10, and AXB11. The PDDs of AXB10 almost agreed with those of MC and AXB11, except for the air cavity. The dose in the air cavity was higher for AXB10 than for AXB11, because their electron cutoff energies are set at 500 and 200 keV, respectively. For head and neck IMRT dose distributions, the D95 in the clinical target volume (CTV) for AAA was almost the same as that for AXB10 and was approximately 7 % larger than that for MC. Comparing each approach with MC using a criterion of 3 %/3 mm, the pass rates for AXB10, AXB11, and AAA were 92.4, 94.7, and 90.4 % in the CTV, respectively. In conclusion, AAA produces dose errors in heterogeneous regions, while AXB11 provides calculation accuracy comparable to MC. AXB10 overestimates the dose in regions that include an air cavity.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/radioterapia , Imagens de Fantasmas , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica , Interface Usuário-Computador
8.
J Cardiol ; 68(4): 316-23, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26620846

RESUMO

BACKGROUND: Comprehensive evaluation of endothelium-dependent and endothelium-independent vascular functions in peripheral arteries and coronary arteries in smokers has never been performed previously. Through the use of brachial artery ultrasound and oxygen-15-labeled water positron emission tomography (PET), we sought to investigate peripheral and coronary vascular dysfunctions in smokers. METHODS AND RESULTS: Eight smokers and 10 healthy individuals underwent brachial artery ultrasound at rest, during reactive hyperemia [250mmHg cuff occlusion (flow-mediated dilatation (FMD)], and following sublingual nitroglycerin (NTG) administration. Myocardial blood flow (MBF) was assessed through O-15-labeled water PET at rest, during adenosine triphosphate (ATP) administration, and during a cold pressor test (CPT). Through ultrasound, smokers were shown to have significantly reduced %FMD compared to controls (6.62±2.28% vs. 11.29±2.75%, p=0.0014). As assessed by O-15-labeled water PET, smokers were shown to have a significantly lower CPT response than were controls (21.1±9.5% vs. 50.9±16.9%, p=0.0004). There was no relationship between %FMD and CPT response (r=0.40, p=0.097). Endothelium-independent vascular dilatation was similar for both groups in terms of coronary flow reserve with PET (p=0.19). Smokers tended to have lower %NTG in the brachial artery (p=0.055). CONCLUSIONS: Smokers exhibited impaired coronary endothelial function as well as peripheral brachial artery endothelial function. In addition, there was no correlation between PET and ultrasound measurements, possibly implying that while smokers may have systemic vascular endothelial dysfunction, the characteristics of that dysfunction may be different in peripheral arteries and coronary arteries.


Assuntos
Artéria Braquial/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/fisiopatologia , Fumar/fisiopatologia , Adulto , Artéria Braquial/fisiopatologia , Estudos de Casos e Controles , Vasos Coronários/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Ultrassonografia , Adulto Jovem
9.
Phys Med Biol ; 60(11): 4517-31, 2015 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-25992894

RESUMO

The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a (60)Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the CTDIair measurement.


Assuntos
Algoritmos , Imagens de Fantasmas , Fótons , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Calibragem , Método de Monte Carlo , Radiometria/instrumentação , Radiometria/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Água/química , Raios X
10.
Hypertens Res ; 38(7): 478-84, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25693851

RESUMO

Increasing vascular diameter and attenuated vascular elasticity may be reliable markers for atherosclerotic risk assessment. However, previous measurements have been complex, operator-dependent or invasive. Recently, we developed a new automated oscillometric method to measure a brachial artery's estimated area (eA) and volume elastic modulus (V(E)). The aim of this study was to investigate the reliability of new automated oscillometric measurement of eA and V(E). Rest eA and V(E) were measured using the recently developed automated detector with the oscillometric method. eA was estimated using pressure/volume curves and V(E) was defined as follows (V(E)=Δ pressure/ (100 × Δ area/area) mm Hg/%). Sixteen volunteers (age 35.2±13.1 years) underwent the oscillometric measurements and brachial ultrasound at rest and under nitroglycerin (NTG) administration. Oscillometric measurement was performed twice on different days. The rest eA correlated with ultrasound-measured brachial artery area (r=0.77, P<0.001). Rest eA and VE measurement showed good reproducibility (eA: intraclass correlation coefficient (ICC)=0.88, V(E): ICC=0.78). Under NTG stress, eA was significantly increased (12.3±3.0 vs. 17.1±4.6 mm(2), P<0.001), and this was similar to the case with ultrasound evaluation (4.46±0.72 vs. 4.73±0.75 mm, P<0.001). V(E) was also decreased (0.81±0.16 vs. 0.65±0.11 mm Hg/%, P<0.001) after NTG. Cross-sectional vascular area calculated using this automated oscillometric measurement correlated with ultrasound measurement and showed good reproducibility. Therefore, this is a reliable approach and this modality may have practical application to automatically assess muscular artery diameter and elasticity in clinical or epidemiological settings.


Assuntos
Artéria Braquial/anatomia & histologia , Artéria Braquial/diagnóstico por imagem , Módulo de Elasticidade , Oscilometria/métodos , Adulto , Envelhecimento/fisiologia , Anatomia Transversal , Artéria Braquial/efeitos dos fármacos , Módulo de Elasticidade/efeitos dos fármacos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Nitroglicerina/farmacologia , Pressão , Reprodutibilidade dos Testes , Ultrassonografia , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologia
11.
J Magn Reson Imaging ; 42(3): 754-62, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25557072

RESUMO

BACKGROUND: To develop and validate a method for quantifying myocardial blood flow (MBF) using dynamic perfusion magnetic resonance imaging (MBFMRI ) at 3.0 Tesla (T) and compare the findings with those of (15) O-water positron emission tomography (MBFPET ). METHODS: Twenty healthy male volunteers underwent magnetic resonance imaging (MRI) and (15) O-water positron emission tomography (PET) at rest and during adenosine triphosphate infusion. The single-tissue compartment model was used to estimate the inflow rate constant (K1). We estimated the extraction fraction of Gd-DTPA using K1 and MBF values obtained from (15) O-water PET for the first 10 subjects. For validation, we calculated MBFMRI values for the remaining 10 subjects and compared them with the MBFPET values. In addition, we compared MBFMRI values of 10 patients with coronary artery disease with those of healthy subjects. RESULTS: The mean resting and stress MBFMRI values were 0.76 ± 0.10 and 3.04 ± 0.82 mL/min/g, respectively, and showed excellent correlation with the mean MBFPET values (r = 0.96, P < 0.01). The mean stress MBFMRI value was significantly lower for the patients (1.92 ± 0.37) than for the healthy subjects (P < 0.001). CONCLUSION: The use of dynamic perfusion MRI at 3T is useful for estimating MBF and can be applied for patients with coronary artery disease.


Assuntos
Circulação Coronária/fisiologia , Angiografia por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Adulto , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/patologia , Gadolínio DTPA/química , Voluntários Saudáveis , Hemodinâmica , Humanos , Masculino , Variações Dependentes do Observador , Radioisótopos de Oxigênio/química , Perfusão , Imagens de Fantasmas , Estudos Prospectivos , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Água , Adulto Jovem
12.
Ann Nucl Med ; 29(1): 15-20, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25209232

RESUMO

OBJECTIVE: (11)C-acetate has been applied for evaluation of myocardial oxidative metabolism and can simultaneously estimate myocardial blood flow (MBF). We developed a new method using two-parameter spillover correction to estimate regional MBF (rMBF) with (11)C-acetate PET in reference to MBF derived from (15)O-H2O PET. The usefulness of our new approach was evaluated compared to the conventional method using one-parameter spillover correction. METHODS: Sixty-three subjects were examined with (11)C-acetate and (15)O-H2O dynamic PET at rest. Inflow rate of (11)C-acetate (K1) was compared with MBF derived from (15)O-H2O PET. For the derivation, the relationship between K1 and MBF from (15)O-H2O was linked by the Renkin-Crone model in 20 subjects as a pilot group. One-parameter and two-parameter corrections were applied to suppress the spillover between left ventricular (LV) wall and LV cavity. Validation was set using the other 43 subjects' data. Finally, rMBFs were calculated using relational expression derived from the pilot-group data. RESULTS: The relationship between K1 and MBF derived from (15)O-H2O PET was approximated as K1 = [1-0.764 × exp(-1.001/MBF)] MBF from the pilot data using the two-parameter method. In the validation set, the correlation coefficient between rMBF from (11)C-acetate and (15)O-H2O demonstrated a significantly higher relationship with the two-parameter spillover correction method than the one-parameter spillover correction method (r = 0.730, 0.592, respectively, p < 0.05). CONCLUSION: In (11)C-acetate PET study, the new two-parameter spillover correction method dedicated more accurate and robust myocardial blood flow than the conventional one-parameter method.


Assuntos
Acetatos , Radioisótopos de Carbono , Circulação Coronária/fisiologia , Modelos Cardiovasculares , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Projetos Piloto , Processamento de Sinais Assistido por Computador , Água
13.
Phys Med Biol ; 59(23): 7297-313, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25383908

RESUMO

In this study, we develope a novel method to directly evaluate an absorbed dose-to-water for kilovoltage-cone beam computed tomography (kV-CBCT) in image-guided radiation therapy (IGRT). Absorbed doses for the kV-CBCT systems of the Varian On-Board Imager (OBI) and the Elekta X-ray Volumetric Imager (XVI) were measured by a Farmer ionization chamber with a (60)Co calibration factor. The chamber measurements were performed at the center and four peripheral points in body-type (30 cm diameter and 51 cm length) and head-type (16 cm diameter and 33 cm length) cylindrical water phantoms. The measured ionization was converted to the absorbed dose-to-water by using a (60)Co calibration factor and a Monte Carlo (MC)-calculated beam quality conversion factor, kQ, for (60)Co to kV-CBCT. The irradiation for OBI and XVI was performed with pelvis and head modes for the body- and the head-type phantoms, respectively. In addition, the dose distributions in the phantom for both kV-CBCT systems were calculated with MC method and were compared with measured values. The MC-calculated doses were calibrated at the center in the water phantom and compared with measured doses at four peripheral points. The measured absorbed doses at the center in the body-type phantom were 1.96 cGy for OBI and 0.83 cGy for XVI. The peripheral doses were 2.36-2.90 cGy for OBI and 0.83-1.06 cGy for XVI. The doses for XVI were lower up to approximately one-third of those for OBI. Similarly, the measured doses at the center in the head-type phantom were 0.48 cGy for OBI and 0.21 cGy for XVI. The peripheral doses were 0.26-0.66 cGy for OBI and 0.16-0.30 cGy for XVI. The calculated peripheral doses agreed within 3% in the pelvis mode and within 4% in the head mode with measured doses for both kV-CBCT systems. In addition, the absorbed dose determined in this study was approximately 4% lower than that in TG-61 but the absorbed dose by both methods was in agreement within their combined uncertainty. This method is more robust and accurate compared to the dosimetry based on a conventional air-kerma calibration factor. Therefore, it is possible to be used as a standard dosimetry protocol for kV-CBCT in IGRT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Radiometria/métodos , Radioterapia Guiada por Imagem , Algoritmos , Calibragem , Imagens de Fantasmas , Radiometria/normas
14.
Endocr J ; 61(12): 1171-80, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25214026

RESUMO

Effective treatments for malignant neuroendocrine tumors are under development. While iodine-131 metaiodobenzylguanidine (¹³¹I-MIBG) radiotherapy has been used in the treatment of malignant neuroendocrine tumors, there are few studies evaluating its therapeutic effects and safety in a multicenter cohort. In the current study, we sought to evaluate the effects and safety of ¹³¹I-MIBG therapy for conditions including malignant pheochromocytoma and paraganglioma within a multicenter cohort. Forty-eight malignant neuroendocrine tumors (37 pheochromocytoma and 11 paraganglioma) from four centers underwent clinical ¹³¹I-MIBG radiotherapy. The tumor responses were observed before and 3 to 6 months after the ¹³¹I-MIBG radiotherapy in accordance with RECIST criteria. We also evaluated the data for any adverse effects. The four centers performed a total of 87 ¹³¹I-MIBG treatments on 48 patients between January 2000 and March 2009. Of the treatments, 65 were evaluable using RECIST criteria. One partial response (PR), 40 stable disease (SD), and 9 progressive disease (PD) in malignant pheochromocytoma were observed after each treatment. Fourteen SD and one PD-were observed in paraganglioma. Patients with normal hypertension (systolic blood pressure (BP) > 130 mmHg) showed significantly reduced systolic BP after the initial follow-up (n=10, 138.1±8.2 to 129.5±13.5 mmHg, P=0.03). In adult neuroendocrine tumors with a treatment-basis analysis, there were side effects following 41 treatments (47.1%) and most of them (90.2%) were minor. In this multicenter registry, PR or SD was achieved in 84.6% of the treatment occasions in adult neuroendocrine tumors through ¹³¹I-MIBG radiotherapy. This indicated that most of the ¹³¹I-MIBG radiotherapy was performed safely without significant side effects.


Assuntos
3-Iodobenzilguanidina/uso terapêutico , Neoplasias das Glândulas Suprarrenais/radioterapia , Paraganglioma/radioterapia , Feocromocitoma/radioterapia , Compostos Radiofarmacêuticos/uso terapêutico , 3-Iodobenzilguanidina/efeitos adversos , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/fisiopatologia , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/metabolismo , Glândulas Suprarrenais/efeitos da radiação , Adulto , Idoso , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Hospitais Universitários , Humanos , Hipertensão/induzido quimicamente , Hipertensão/etiologia , Hipertensão/prevenção & controle , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/uso terapêutico , Japão , Masculino , Pessoa de Meia-Idade , Paraganglioma/diagnóstico por imagem , Paraganglioma/metabolismo , Paraganglioma/fisiopatologia , Feocromocitoma/diagnóstico por imagem , Feocromocitoma/metabolismo , Feocromocitoma/fisiopatologia , Cintilografia , Compostos Radiofarmacêuticos/efeitos adversos , Sistema de Registros
15.
Ann Nucl Med ; 28(8): 761-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24950751

RESUMO

OBJECTIVES: (123)I-metaiodobenzylguanidine (MIBG) has been used to estimate cardiac sympathetic nervous innervation. Heterogeneous MIBG distribution is mainly associated with high physiological MIBG uptakes in the liver. We postulate that prone position acquisition might be especially effective for MIBG, providing for separation from high liver uptake similar to that provided by perfusion single-photon emission computed tomography (SPECT). We investigated whether prone-position acquisition improved MIBG image quality by comparing our results to those acquired using supine MIBG and high-quality (11)C-hydroxyephedrine (HED) positron emission tomography/computed tomography PET/CT. METHODS: Ten male volunteers (body mass index (BMI) 22.7 ± 3.4) underwent prone and supine MIBG and HED PET. Relative regional tracer uptake was estimated in early MIBG and HED. Acquired images were divided into 17 segments and were grouped into 4 regions: anterior, inferior, septum, and lateral. For each patient, the inferior/anterior ratio was calculated. RESULTS: The quality of images acquired using prone MIBG was better than that using supine MIBG (p < 0.05). Inferior and septum relative MIBG uptake was reduced in comparison with anterior or lateral MIBG uptake in the supine position (inferior vs. anterior: 69.0 ± 5.6 vs. 82.3 ± 4.6 %, p < 0.01; septum vs. lateral: 66.2 ± 5.1 vs. 81.9 ± 5.4 %, p < 0.01). Prone MIBG showed a significantly higher inferior/anterior uptake ratio in comparison with supine MIBG (n = 24, seg: 92.2 ± 7.2 vs. 83.6 ± 5.7 %, p < 0.05). However, intergroup differences in uptake ratio were demonstrated among prone and supine MIBG and HED. HED PET/CT still showed a higher uptake ratio in comparison with prone MIBG SPECT (103.9 ± 8.0 vs. 92.2 ± 7.2 %, p < 0.05). CONCLUSION: Even in normal male subjects, standard supine MIBG imaging showed reduced inferior and septum uptake. Uptake with prone MIBG imaging showed a significant improvement over that with supine imaging and was closer to uptake for HED PET/CT. This improvement may be the result of preventing intense uptake by the liver. Prone data acquisition may be a viable alternative in evaluating regional abnormalities using MIBG SPECT in men.


Assuntos
3-Iodobenzilguanidina , Efedrina , Coração/diagnóstico por imagem , Radioisótopos do Iodo , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Peso Corporal , Isótopos de Carbono , Catecolaminas/sangue , Voluntários Saudáveis , Hemodinâmica , Humanos , Fígado/diagnóstico por imagem , Masculino , Miocárdio/patologia , Decúbito Ventral , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
16.
Radiol Phys Technol ; 7(2): 303-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24796955

RESUMO

Our purpose in this study was to implement three-dimensional (3D) gamma analysis for structures of interest such as the planning target volume (PTV) or clinical target volume (CTV), and organs at risk (OARs) for intensity-modulated radiation therapy (IMRT) dose verification. IMRT dose distributions for prostate and head and neck (HN) cancer patients were calculated with an analytical anisotropic algorithm in an Eclipse (Varian Medical Systems) treatment planning system (TPS) and by Monte Carlo (MC) simulation. The MC dose distributions were calculated with EGSnrc/BEAMnrc and DOSXYZnrc user codes under conditions identical to those for the TPS. The prescribed doses were 76 Gy/38 fractions with five-field IMRT for the prostate and 33 Gy/17 fractions with seven-field IMRT for the HN. TPS dose distributions were verified by the gamma passing rates for the whole calculated volume, PTV or CTV, and OARs by use of 3D gamma analysis with reference to MC dose distributions. The acceptance criteria for the 3D gamma analysis were 3/3 and 2 %/2 mm for a dose difference and a distance to agreement. The gamma passing rates in PTV and OARs for the prostate IMRT plan were close to 100 %. For the HN IMRT plan, the passing rates of 2 %/2 mm in CTV and OARs were substantially lower because inhomogeneous tissues such as bone and air in the HN are included in the calculation area. 3D gamma analysis for individual structures is useful for IMRT dose verification.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Radiometria , Radioterapia de Intensidade Modulada/efeitos adversos , Software
17.
Eur Radiol ; 24(7): 1547-56, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24744200

RESUMO

OBJECTIVES: This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H2O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. METHODS: Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). RESULTS: Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). CONCLUSIONS: We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. KEY POINTS: • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluxo Sanguíneo Regional/fisiologia , Adulto , Idoso , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes
18.
Eur J Nucl Med Mol Imaging ; 41(6): 1240-50, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24615469

RESUMO

PURPOSE: The right ventricle (RV) has a high capacity to adapt to pressure or volume overload before failing. However, the mechanisms of RV adaptation, in particular RV energetics, in patients with pulmonary hypertension (PH) are still not well understood. We aimed to evaluate RV energetics including RV oxidative metabolism, power and efficiency to adapt to increasing pressure overload in patients with PH using (11)C-acetate PET. METHODS: In this prospective study, 27 patients with WHO functional class II/III PH (mean pulmonary arterial pressure 39.8 ± 13.5 mmHg) and 9 healthy individuals underwent (11)C-acetate PET. (11)C-acetate PET was used to simultaneously measure oxidative metabolism (k mono) for the left ventricle (LV) and RV. LV and RV efficiency were also calculated. RESULTS: The RV ejection fraction in PH patients was lower than in controls (p = 0.0054). There was no statistically significant difference in LV k mono (p = 0.09). In contrast, PH patients showed higher RV k mono than did controls (0.050 ± 0.009 min(-1) vs. 0.030 ± 0.006 min(-1), p < 0.0001). PH patients exhibited significantly increased RV power (p < 0.001) and hence increased RV efficiency compared to controls (0.40 ± 0.14 vs. 0.017 ± 0.12 mmHg·mL·min/g, p = 0.001). CONCLUSION: The RV oxidative metabolic rate was increased in patients with PH. Patients with WHO functional class II/III PH also had increased RV power and efficiency. These findings may indicate a myocardial energetics adaptation response to increasing pulmonary arterial pressure.


Assuntos
Acetatos , Carbono , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/metabolismo , Humanos , Hipertensão Pulmonar/metabolismo , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Direita
19.
Circ J ; 77(7): 1662-71, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23698028

RESUMO

Myocardial perfusion imaging (MPI) has played an important role in the diagnosis and risk assessment of coronary artery disease (CAD) since the early 1970s. Positron emission tomography (PET) MPI has high diagnostic accuracy and prognostic value. PET MPI can also be used to quantitatively evaluate regional myocardial blood flow (MBF) through a mathematical model. PET MBF measurements can be used in evaluating early-stage atherosclerosis with endothelial dysfunction right through to diagnosing CAD. PET/computed tomography scanners are now found in many facilities across North America, Europe, and Asia, and PET MBF quantification is expected to move from strictly research to more clinical applications. Nuclear cardiology has been a leader in quantification approaches that can be applied to other new imaging modalities. Therefore, it would be valuable to understand the basic aspects of quantification approaches. This review will address the basic aspects of MBF quantification and the additional value of quantification approaches in the clinical setting.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária , Modelos Cardiovasculares , Miocárdio , Tomografia por Emissão de Pósitrons/métodos , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino
20.
J Nucl Cardiol ; 19(4): 763-74, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22527800

RESUMO

PURPOSE: Myocardial blood flow (MBF) estimation with (82)Rubidium ((82)Rb) positron emission tomography (PET) is technically difficult because of the high spillover between regions of interest, especially due to the long positron range. We sought to develop a new algorithm to reduce the spillover in image-derived blood activity curves, using non-uniform weighted least-squares fitting. METHODS: Fourteen volunteers underwent imaging with both 3-dimensional (3D) (82)Rb and (15)O-water PET at rest and during pharmacological stress. Whole left ventricular (LV) (82)Rb MBF was estimated using a one-compartment model, including a myocardium-to-blood spillover correction to estimate the corresponding blood input function Ca(t)(whole). Regional K1 values were calculated using this uniform global input function, which simplifies equations and enables robust estimation of MBF. To assess the robustness of the modified algorithm, inter-operator repeatability of 3D (82)Rb MBF was compared with a previously established method. RESULTS: Whole LV correlation of (82)Rb MBF with (15)O-water MBF was better (P < .01) with the modified spillover correction method (r = 0.92 vs r = 0.60). The modified method also yielded significantly improved inter-operator repeatability of regional MBF quantification (r = 0.89) versus the established method (r = 0.82) (P < .01). CONCLUSION: A uniform global input function can suppress LV spillover into the image-derived blood input function, resulting in improved precision for MBF quantification with 3D (82)Rb PET.


Assuntos
Circulação Coronária , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio/farmacologia , Adulto , Algoritmos , Simulação por Computador , Eletrocardiografia/métodos , Feminino , Humanos , Imageamento Tridimensional , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Variações Dependentes do Observador , Radioisótopos de Oxigênio/química , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...